<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-20 09-10-31
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 61 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.9 kHz -8 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
16 kHz 71 kHz 10099 2,0002
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,0 dBr 7,42 dBr 8,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 9:10, 20.02.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (60 dBuV) Max at: 71 kHz MIN: 16 kHz % above 75 kHz: 2,0002 Acquired: 2025/02/20 9:09:28 Total samples: 10099 Equivalent time: 0:08:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,0 dBr MIN: 6,0 dBr AVE: 7,42 dBr % above 10,0 dBr: 0,0 Last value: 6,0 dBr (2025/02/20 9:09:27) Station: 96.90 MHz, signal: 5/5 (61 dBuV) 09:03 09:04 09:05 09:06 09:07 09:08 09:09 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality